University of Leicester
Browse
1/1
2 files

Automatic segmentation of coronary morphology using transmittance based lumen intensity-enhanced intravascular optical coherence tomography images and applying a localized level-set based active contour method

journal contribution
posted on 2016-11-07, 15:45 authored by Shiju Joseph, Asif Adnan, David Adlam
Lumen segmentation from clinical intravascular optical coherence tomography (IV-OCT) images has clinical relevance as it provides a full three dimensional (3D) perspective of diseased coronary artery sections. Inaccurate segmentation may occur when there are artefacts in the image, resulting from issues such as inadequate blood clearance. This study proposes a transmittance based lumen intensity enhancement method that ensures lumen regions only are highlighted. A level-set based active contour method (ACM) that utilizes the local speckle distribution properties of the image, is then employed to drive an imagespecific active contour towards the true lumen boundaries. By utilizing local speckle properties, the intensity variation issues within the image are resolved. This combined approach has been successfully applied to challenging clinical IV-OCT datasets that contains multiple lumens, residual blood flow and its shadowing artefact. A method to identify the guide-wire and interpolate the lost lumen segments has been implemented. This approach is fast and can perform even when guide-wire boundaries are not easily identified. Lumen enhancement also makes it easy to identify vessel side branches. This automated approach is not only able to extract the arterial lumen, but also the smaller microvascular lumens that are associated with the vasa vasorum and with atherosclerotic plaque

Funding

The work reported in this paper is supported by St Jude Medical UK Limited and NIHR Leicester Cardiovascular Biomedical Research Unit, UK. This research used the ALICE High Performance Computing Facility at the University of Leicester.

History

Citation

Journal of Medical Imaging 3(4), 044001 (Nov 29, 2016)

Author affiliation

/Organisation/COLLEGE OF MEDICINE, BIOLOGICAL SCIENCES AND PSYCHOLOGY/School of Medicine/Department of Cardiovascular Sciences

Version

  • AM (Accepted Manuscript)

Published in

Journal of Medical Imaging 3(4)

Publisher

Society of Photo-optical Instrumentation Engineers (SPIE)

issn

0920-5497

eissn

2329-4310

Acceptance date

2016-11-01

Available date

2016-12-02

Publisher version

http://medicalimaging.spiedigitallibrary.org/article.aspx?articleid=2589488

Language

en

Usage metrics

    University of Leicester Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC