posted on 2019-09-23, 16:31 authored by MJ Wilde, RL Cordell, D Salman, B Zhao, W Ibrahim, L Bryant, D Ruszkiewicz, A Singapuri, RC Free, EA Gaillard, C Beardsmore, CLP Thomas, CE Brightling, S Siddiqui, PS Monks
Precision medicine has spurred new innovations in molecular pathology leading to recent advances in the analysis of exhaled breath as a non-invasive diagnostic tool. Volatile organic compounds (VOCs) detected in exhaled breath have the potential to reveal a wealth of chemical and metabolomic information. This study describes the development of a method for the analysis of breath, based on automated thermal desorption (TD) combined with flow modulated comprehensive two-dimensional gas chromatography (GC×GC) with dual flame ionisation and quadrupole mass spectrometric detection (FID and qMS). The constrained optimisation and analytical protocol was designed to meet the practical demands of a large-scale multi-site clinical study, while maintaining analytical rigour to produce high fidelity data. The results demonstrate a comprehensive method optimisation for the collection and analysis of breath VOCs by GC×GC, integral to the standardisation and integration of breath analysis within large clinical studies.

Funding

Research funding was provided by the Medical Reseach Council (MRC) and Engineering and Physical Science Research Council (EPSRC) Stratified Medicine Grant for Molecular Pathology Nodes (Grant No. MR/N005880/1). The research was supported by the National Institute for Health Research (NIHR) Leicester Biomedical Research Centre and NIHR Leicester Clinical Research Facility to whom we are extremely grateful. The children’s component of this study is supported by The Midlands Asthma and Allergy Research Association (MAARA), (Grant No. MR/N005880/1). The authors would like to acknowledge the invaluable efforts of the research nurses responsible for the in-clinic sample collection as well as the input from the wider EMBER consortium (Members list can be found at: https://ember.le.ac.uk/web). The views expressed are those of the author(s) and not necessarily those of the NHS and NIHR or the Department of Health.

History

Citation

Journal of Chromatography A, 2019, 1594, pp. 160-172

Author affiliation

/Organisation/COLLEGE OF SCIENCE AND ENGINEERING

Version

  • VoR (Version of Record)

Published in

Journal of Chromatography A

Publisher

Elsevier

eissn

1873-3778

Acceptance date

2019-02-01

Copyright date

2019

Available date

2019-09-23

Publisher version

https://www.sciencedirect.com/science/article/pii/S0021967319301311?via=ihub

Notes

Supplementary material related to this article can be found, in the online version, at doi:https://doi.org/10.1016/j.chroma.2019.02.001.

Language

en

Usage metrics

    University of Leicester Publications

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC