University of Leicester
Browse

High mass accuracy assay for trimethylamine N-oxide using stable-isotope dilution with liquid chromatography coupled to orthogonal acceleration time of flight mass spectrometry with multiple reaction monitoring

journal contribution
posted on 2015-11-02, 11:02 authored by Liam M. Heaney, Donald J. L. Jones, Richard J. Mbasu, Leong L. Ng, Toru Suzuki
Trimethylamine N-oxide (TMAO) has attracted interest as circulating levels have reported prognostic value in patients with cardiovascular conditions, such as heart failure. With continual advances in accurate mass measurements, robust methods that can employ the capabilities of time of flight mass spectrometers would offer additional utility in the analysis of complex clinical samples. A Waters Acquity UPLC was coupled to a Waters Synapt G2-S high-resolution mass spectrometer. TMAO was measured in plasma by stable-isotope dilution-hydrophilic interaction liquid chromatography-time of flight mass spectrometry with multiple reaction monitoring (LC-ToF-MRM). Two transitions were monitored: m/z 76.1 to 58.066/59.073 and m/z 85.1 to 66.116/68.130. The method was assessed for linearity, lower limits of detection and quantitation, and reproducibility. A selected cohort of patients with systolic heart failure (SHF; n = 43) and healthy controls (n = 42) were measured to verify the assay is suitable for the analysis of clinical samples. Quantitative analysis of TMAO using LC-ToF-MRM enabled linearity to be established between 0.1 and 75 μmol/L, with a lower limit of detection of 0.05 μmol/L. Relative standard deviations reported an inter-day variation of ≤20.8 % and an intra-day variation of ≤11.4 % with an intra-study quality control variation of 2.7 %. Run times were 2.5 min. Clinical application of the method reported that TMAO in SHF was elevated compared to that of healthy controls (p < 0.0005). LC-ToF-MRM offers a highly selective method for accurate mass measurement of TMAO with rapid and reproducible results. Applicability of the method was shown in a selected cohort of patient samples.

History

Citation

Analytical and Bioanalytical Chemistry (Online First)

Author affiliation

/Organisation/COLLEGE OF MEDICINE, BIOLOGICAL SCIENCES AND PSYCHOLOGY/School of Medicine/Department of Cancer Studies and Molecular Medicine

Version

  • AM (Accepted Manuscript)

Published in

Analytical and Bioanalytical Chemistry (Online First)

Publisher

Springer Verlag

issn

1618-2642

eissn

1618-2650

Acceptance date

2015-10-29

Copyright date

2015

Available date

2016-11-14

Publisher version

http://link.springer.com/article/10.1007/s00216-015-9164-6

Notes

The file associated with this record is under a 12-month embargo from publication in accordance with the publisher's self-archiving policy, available at http://www.springer.com/gp/open-access/authors-rights/self-archiving-policy/2124. The full text may be available through the publisher links provided above.

Language

en

Usage metrics

    University of Leicester Publications

    Categories

    No categories selected

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC