posted on 2019-07-18, 11:30 authored by E Moss, P Sarhanis, T Ind, M Smith, Q Davies, M Zecca
Study Objective
Work-related musculoskeletal symptoms (WMSs) are reported to be increasing in surgeons performing minimally invasive procedures. Therefore, we investigated the use of inertial measurement units (IMUs) and electromyography (EMG) sensor recorders to record real-time information on the muscle movement/activity required to perform training exercises in simulated in normal and high body mass index (BMI) models.

Design
Prospective study.

Setting
University hospital.

Participants
Four consultant gynecologic oncology surgeons experienced in complex straight-stick (SS) laparoscopic and robotically assisted (RA) surgery.

Interventions
Three exercises (hoops onto pegs and wire chase) using SS and RA surgery on 2 abdominal models: normal BMI and high BMI.

Measurements and Main Results
We measured time to complete exercise and surgeon muscle movement/activity. The time to complete all exercises was significantly lower for RA surgery as compared with SS laparoscopy (p <.05 or better). The movement of the surgeons’ core was significantly greater in high BMI SS laparoscopy compared with normal BMI SS laparoscopy for exercises 1 and 2 (p <.001). Muscle usage, as determined by EMG peak, was significantly higher in normal BMI SS laparoscopy and even higher in high BMI SS laparoscopy but was generally flat for all normal and high BMI RA surgery exercises (p <.05 or better).

Conclusion
Detailed real-time information can be collected through IMUs/EMG sensors. Our results indicate that RA surgery requires less surgeon movements and muscle activity to complete tasks compared with SS laparoscopy, particularly in a high BMI model. The implications of these results are that RA surgery in high BMI patients may therefore have less physical impact on the surgeon compared with SS laparoscopy and may result in lower WMS rates.

Funding

Intuitive Surgical provided the robotic instruments and the abdominal model on which the exercises were performed.

History

Citation

Journal of Minimally Invasive Gynecology, Volume 27, Issue 5, July–August 2020, Pages 1063-1069

Author affiliation

/Organisation/COLLEGE OF LIFE SCIENCES/School of Medicine/Cancer Research Centre

Version

  • AM (Accepted Manuscript)

Published in

Journal of Minimally Invasive Gynecology

Volume

27

Issue

5

Pagination

1063-1069

Publisher

Elsevier

eissn

1553-4669

Acceptance date

2019-07-13

Copyright date

2019

Available date

2020-07-18

Notes

The file associated with this record is under embargo until 12 months after publication, in accordance with the publisher's self-archiving policy. The full text may be available through the publisher links provided above.

Language

en

Usage metrics

    University of Leicester Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC