OBJECTIVE: PaCO2 affects cerebral blood flow (CBF) and its regulatory mechanisms, but the effects of CO2 measurement technique on cerebrovascular parameters are unknown. In order to determine if the two most commonly used approaches, face mask (FM) or nasal cannulae (NC), are interchangeable or not, we tested the hypothesis that the use of FM versus NC does not lead to significant differences in CO2-related systemic and cerebrovascular parameters. APPROACH: Recordings of CBF velocity (CBFV), blood pressure (BP), heart rate, and end-tidal CO2 (EtCO2) were performed in 42 subjects during normocapnia (FM or NC) and 5% CO2 inhalation (FM) or hyperventilation (NC). Dynamic cerebral autoregulation was assessed with the autoregulation index (ARI), derived by transfer function analysis from the CBFV response to a hypothetical step change in BP. MAIN RESULTS: Significant differences in physiological parameters were seen between FM and NC: EtCO2 (37.40 versus 35.26 mmHg, p  =  0.001) and heart rate (69.6 versus 66.7 bpm, p  =  0.001) respectively. No differences were observed for mean BP, CBFV or the ARI index. SIGNIFICANCE: Use of FM or NC for measurement of EtCO2 leads to physiological changes and differences in parameter values that need to be taken into consideration when interpreting and/or comparing results in studies of cerebral haemodynamics.

History

Citation

Physiological Measurement, 2017, 38 (7), pp. N101-N106

Author affiliation

/Organisation/COLLEGE OF MEDICINE, BIOLOGICAL SCIENCES AND PSYCHOLOGY/School of Medicine/Department of Cardiovascular Sciences

Version

  • AM (Accepted Manuscript)

Published in

Physiological Measurement

Publisher

IOP Publishing

issn

0967-3334

eissn

1361-6579

Acceptance date

2017-04-26

Copyright date

2017

Available date

2018-06-22

Publisher version

http://iopscience.iop.org/article/10.1088/1361-6579/aa6f9f

Notes

The file associated with this record is under embargo until 12 months after publication, in accordance with the publisher's self-archiving policy. The full text may be available through the publisher links provided above.

Language

en

Usage metrics

    University of Leicester Publications

    Categories

    No categories selected

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC