University of Leicester
Browse
- No file added yet -

Physical Activity Assessed by Wrist and Thigh Worn Accelerometry and Associations with Cardiometabolic Health

Download (1.27 MB)
journal contribution
posted on 2023-09-19, 12:31 authored by Benjamin D Maylor, Charlotte L Edwardson, Alexandra M Clarke-Cornwell, Melanie J Davies, Nathan P Dawkins, David W Dunstan, Kamlesh Khunti, Tom Yates, Alex V Rowlands
Physical activity is increasingly being captured by accelerometers worn on different body locations. The aim of this study was to examine the associations between physical activity volume (average acceleration), intensity (intensity gradient) and cardiometabolic health when assessed by a thigh-worn and wrist-worn accelerometer. A sample of 659 office workers wore an Axivity AX3 on the non-dominant wrist and an activPAL3 micro on the right thigh concurrently for 24 h a day for 8 days. An average acceleration (proxy for physical activity volume) and intensity gradient (intensity distribution) were calculated from both devices using the open-source raw accelerometer processing software GGIR. Clustered cardiometabolic risk (CMR) was calculated using markers of cardiometabolic health, including waist circumference, triglycerides, HDL-cholesterol, mean arterial pressure and fasting glucose. Linear regression analysis assessed the associations between physical activity volume and intensity gradient with cardiometabolic health. Physical activity volume derived from the thigh-worn activPAL and the wrist-worn Axivity were beneficially associated with CMR and the majority of individual health markers, but associations only remained significant after adjusting for physical activity intensity in the thigh-worn activPAL. Physical activity intensity was associated with CMR score and individual health markers when derived from the wrist-worn Axivity, and these associations were independent of volume. Associations between cardiometabolic health and physical activity volume were similarly captured by the thigh-worn activPAL and the wrist-worn Axivity. However, only the wrist-worn Axivity captured aspects of the intensity distribution associated with cardiometabolic health. This may relate to the reduced range of accelerations detected by the thigh-worn activPAL.

Funding

NIHR Leicester Biomedical Research Centre

History

Author affiliation

Diabetes Research Centre, University of Leicester

Version

  • VoR (Version of Record)

Published in

Sensors

Volume

23

Issue

17

Pagination

7353

Publisher

MDPI AG

eissn

1424-8220

Copyright date

2023

Available date

2023-09-19

Language

en

Usage metrics

    University of Leicester Publications

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC