University of Leicester
Browse

Reliability of measurement of endothelial function across multiple institutions and establishment of reference values in Japanese.

Download (2.44 MB)
journal contribution
posted on 2017-01-20, 12:47 authored by H. Tomiyama, T. Kohro, Y. Higashi, B. Takase, Toru Suzuki, T. Ishizu, S. Ueda, T. Yamazaki, T. Furumoto, K. Kario, T. Inoue, S. Koba, K. Watanabe, Y. Takemoto, T. Hano, M. Sata, Y. Ishibashi, K. Node, K. Maemura, Y. Ohya, T. Furukawa, H. Ito, H. Ikeda, A. Yamashina
AIMS: For the standardization of flow-mediated vasodilatation (FMD) assessment as a clinical tool, validation of its reliability across multiple institutions and the establishment of normal/reference values based on reliable data from multiple institutions are needed. METHODS AND RESULTS: In Study 1, assessment of FMD (scan recording and analysis) using an ultrasonographic semi-automatic measuring system (sFMD) was conducted at 18 participating institutions (sFMD-INST) (n = 981). All of the brachial arterial scans were also analyzed at a core laboratory (sFMD-COLB). After 111 subjects with inadequate sFMD recordings were excluded (n = 880), the correlation between the sFMD-INST and sFMD-COLB improved from R = 0.725 to R = 0.838 (p < 0.001). In Study 2, based on good-quality sFMD data obtained from 6660 subjects without cardiovascular disease (CVD) and 729 subjects with CVD from 27 institutions, reference values of sFMD are proposed by the Framingham risk score (FRS)-based risk categories and according to gender and age. The receiver-operating characteristic curve analysis revealed a significant power of sFMD values in reference ranges to discriminate between subjects with and without CVD (e.g., area under curve = 0.64 in the FRS-low risk group). CONCLUSIONS: When the analysis was limited to cases with clear sFMD recordings, the reliability of the sFMD assessment (scan and its analysis) conducted in individual institutions appeared to be acceptable. Reference sFMD values (lower cuff occlusion) for the Japanese population are proposed based on reliable data derived from multiple institutions, and the reference values may identify patients without advanced vascular damage.

Funding

The present study was supported by the Japanese Atherosclerosis Prevention Research Fund (A study of Multi-center Assessment on the Clinical Usefulness of Semi-automatic Measurement of Flow-mediated Vasodilatation of the Brachial Artery: FMD-J study).

History

Citation

Atherosclerosis, 2015, 242 (2), pp. 433-442

Author affiliation

/Organisation/COLLEGE OF MEDICINE, BIOLOGICAL SCIENCES AND PSYCHOLOGY/School of Medicine/Department of Cardiovascular Sciences

Version

  • VoR (Version of Record)

Published in

Atherosclerosis

Publisher

Elsevier fpr European Atherosclerosis Society, International Atherosclerosis Society, Society of Atherosclerosis Imaging and Prevention

issn

0021-9150

eissn

1879-1484

Acceptance date

2015-08-02

Copyright date

2015

Available date

2017-01-20

Publisher version

http://www.sciencedirect.com/science/article/pii/S0021915015300642

Notes

Supplementary data related to this article can be found at http://dx.doi.org/10.1016/j.atherosclerosis.2015.08.001.