University of Leicester
Browse

An investigation of soft X-ray imaging and polarimetry.

Download (29.65 MB)
thesis
posted on 2015-11-19, 09:17 authored by John Ernest. Lees
This thesis includes work on both microchannel plate X-ray detectors and X-ray polarimetry, which although essentially distinct, have a common link through X-ray photocathodes. The source(s) of the background noise count rate in microchannel plates are investigated. Various noise mechanisms assessed include outgassing, cosmic rays, field emission, internal radioactivity, ion feedback and thermal emission. Experimental measurements are compared with calculations from a Monte Carlo model based on the assumption that radioactive decay (by beta emission) of elements within the microchannel plate glass is the major source of dark noise. The performance of Caesium Bromide as an X-ray photocathode for enhancing the quantum detection efficiency of microchannel plates is reported and compared with that of Caesium Iodide. A new type of microchannel plate configuration, a Sandwich Plate, consisting of three standard microchannel plates bonded in permanent contact is examined for use as an X-ray photon counting detector. This investigation includes a study of the correlation between gain reduction with increased count rate and the size of the illuminated area. An evaluation is made of Galileo Long Life (L2) Microchannel plates operated in pulse counting mode with special emphasis on the stability of the gain as a function of abstracted charge. Further evidence for radioactivity as the major source of background noise is obtained; L2 plates contain different radioactive isotopes compared to the 'standard' (Mullard) microchannel plate glass. The design and performance of a new type of polarimeter, a Photoemission Polarimeter, for use in soft X-ray astronomy is presented. The polarimeter utilises the linear polarisation sensitivity in the photoemission from a CsI photocathode. Possible sources of instrumental modulation are evaluated by comparing experimental measurements with calculations from a Monte Carlo model. The sensitivity of the photoemission polarimeter is compared with X-ray polarimeters presently used in X-ray astronomy.

History

Date of award

1989-01-01

Author affiliation

Physics and Astronomy

Awarding institution

University of Leicester

Qualification level

  • Doctoral

Qualification name

  • PhD

Language

en

Usage metrics

    University of Leicester Theses

    Categories

    No categories selected

    Keywords

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC